Questions You Should Know about Pipe Cap Supplier

pipe - How do I cut and cap copper water tubing cheaply and safely?

In my basement I have copper water pipes that look like they hooked up to an old shower. Now they don't hook up to anything. I want to prune these pipes where they come off the main water line (so I can put a deep freezer in their place) but I've never done anything like that before.

Ziheng Product Page

Google tells me I have two options for pipe fittings: sweating or compression fittings. I want something more or less permanent but I don't to buy extra tools I may not need again for a long time, plus if I can avoid open flames I'd like to, etc. Are compression caps available and suitable for this kind of thing?

PS Can I cut copper pipe with an angle grinder or should I buy a pipe cutter?

Resolution: Thanks for all the advice! In the end I went with a pushfit cap made by SharkBite:

I also bought a handheld, handleless pipe cutter for $7. I shut off the water, cut the pipe, popped on the cap, and turned the water back on. Worked like a charm. The whole job took 20 minutes and cost about $11.

I'll look forward to learning to sweat connections another time. For a casual plumber like me, pushfit fittings cost about 10 times as much as soldering and so worth it.

Compression caps are available and suitable, but you do need to be fairly careful when fitting them that you tighten the joint just the right amount. You also need a reasonable amount of room to be able to turn the spanner/wrench.

Soldering will give you the most professional result and can be done in a fairly confined space - as long as you take the necessary precautions to avoid scorching/burning the surroundings.

If you really can't face the thought of soldering the joints then you can get push fit end caps that work very well. You need to make sure you've got a smooth, straight end to get a good fit, so a pipe cutter is the preferred cutting method. You can use a hacksaw, but you will need to then use emery paper on the end to remove the burr.

answered Jan 14, at 16:24 ChrisF'ChrisF 17k55 gold badges5151 silver badges7474 bronze badges

Frequently Asked Questions (FAQs) - U.S. Pipe

The procedure for installing gaskets is simple.  However, a large part of the reliability of the seal depends on cleanliness of the joint at the time of installation.  Considering the variety of conditions that may be encountered in transit or at the jobsite, it would not be possible to ensure joint cleanliness if the gaskets were pre-installed by the manufacturer.  Pre-installation would also expose gaskets unnecessarily to ultraviolet exposure and even vandalism.

For mechanical joints, the gland should be slipped some distance back from the plain end of the pipe with the lip of the gland facing the bell.  The inside diameter of the mechanical joint gasket is smaller than the outside diameter of the pipe.  Brush the plain end of the pipe and the gasket with an approved pipe lubricant as supplied by the manufacturer.  The gasket must then be stretched over the plain end of the pipe with the thinner side of the wedge facing the bell.  The lubricant allows the gasket to slide more easily into the bell and become equalized as the gland compresses it to achieve a reliable seal.

The TYTON JOINT® and FIELD LOK 350® gaskets have a stiff rim called the heel bonded to a circular cross section called the bulb.  After correct installation, the heel will fit into the first groove just inside the bell.  The bulb will enter the bell first and will be compressed between the inside of the bell at the gasket seat and the outside of the pipe to achieve a seal.  The gasket diameter is larger than the bell opening, so a technique must be followed to allow the gasket to be properly fitted inside the bell.

For smaller pipe, up to about 20', draw a loop of the gasket towards its center forming somewhat of a heart shape.  While holding the loop with one hand, start fitting the gasket heel into the groove of the bell with the other.  Gradually release the loop while pressing the gasket evenly into position around the inside circumference of the bell.  It may be necessary to firmly seat the loop with the heel of the hand to ensure it is fully seated. 

As pipe size increases, it will be necessary to use an increasing number of loops to facilitate gasket installation.  In the largest sizes, it is not uncommon to have as many as eight loops, evenly spaced around the gasket.  Regardless of pipe size, if the gasket has been properly installed, the leading edge of the rubber should be slightly below the smallest part of the bell opening all around the inside circumference.  If any part of the gasket is sticking up, it must be worked until fully seated, or the gasket must be removed and re-installed.

Once the gasket is properly seated, continue with the assembly procedure to make up the joint.

ANSI/AWWA C600 'Installation of Ductile-Iron Water Mains and Their Appurtenances' requires that newly installed Ductile Iron water mains be hydrostatically tested at not less than 1.25 times the working pressure at the highest point along the test section and not less than 1.5 times the working pressure at the lowest point of testing.

After the air has been expelled and the valve or valves segregating the part of the system under test have been closed, pressure is then normally applied with a hand pump, gasoline-powered pump, or fire department pumping equipment for large lines. After the main has been brought up to test pressure, it is held at least two hours and the make-up water measured with a displacement meter or by pumping the water from a vessel of known volume. The make-up water is called the 'testing allowance,' and the allowable amount is a function of length of pipe tested, nominal diameter of the pipe, and the average test pressure. The hydrostatic pressure test helps to identify damaged or defective pipe, fittings, joints, valves, or hydrants, and also the security of the thrust restraint system.

The 'testing allowance' is not a 'leakage allowance.' Properly installed Ductile Iron pipelines with properly assembled joints are bottle-tight and do not leak. The 'testing allowance' is, however, a practical measure used to maintain the pressure, which might actually drop because of factors other than leakage, including trapped air, absorption of water by the cement lining, extension of restrained joints and other small pipe-soil movements, temperature variations during testing, etc.

Yes, you can. Ductile Iron pipe and fittings can be direct tapped for air release valves, sampling ports, service connections, etc. You do want to ensure that there is adequate thread engagement to provide both strength and a leak-free seal. Testing has shown that, with the use of a good thread sealant, as little as one full thread engagement will provide a leak-free tap. Following the conservative nature of our industry, we recommend that you choose at least two full threads of engagement.

The limiting factor in achieving adequate thread engagement for a given metal thickness is the relative curvature of the parent body as the size of the tap increases. There are tables in AWWA/ANSI C151/A21.51 which show the maximum size of tap that can be used on a given size of pipe, and thickness to achieve 2, 3, or 4 thread engagement.

Also, you can order fittings with a boss cast at the location of the desired tap. The flat surface of the boss, along with the increased metal thickness, provides for multiple thread engagement of tap sizes larger than could be accommodated on the curved surface of the fitting.

The advantages of using push-on fittings are the same as for using push-on pipe. Push-on fittings like U.S. Pipe's TYTON JOINT® Fittings result in a more reliable joint, with much less labor. The reliability of a mechanical joint is very dependent on the skill of the installer, who must ensure that the bolts at the bottom of the joint in a muddy trench get the same uniform torque as the others.

When joints must be restrained, the use of mechanical joint retainer glands requires approximately twice as much labor to install as an unrestrained mechanical joint. Both require significantly more time and effort to install than U.S. Pipe's restrained push-on joints: the TYTON JOINT® with FIELD LOK 350® Gaskets, and the TR FLEX® Joint.

Some contractors tell us that push-on fittings are more difficult to install than mechanical joint fittings. There is no question that the two joints require slightly different procedures to install. However, there is ample evidence to show that contractors who have become comfortable with the technique of installing push-on fittings spend more time laying pipe and less time chasing joint leaks.

No. Usually, a pipeline flowing constantly maintains a fairly even temperature. TR FLEX® Pipe should always be extended at installation to engage the locking segments which provide joint restraint. When the joint is properly extended, there is sufficient clearance between the face of the pipe plain end and the back of the adjoining bell to accommodate slight changes in length due to thermal effects.

If a TR FLEX Telescoping Sleeve is installed above ground, internal pressure will usually extend the sleeve to its maximum length. In the case of a bridge crossing where the ends of the pipeline are usually fixed, the increase in length often causes the pipeline to snake. A zigzag pipeline is not only aesthetically not pleasing, it can also result in over-deflection at the joints.

The exception to this recommendation is where a pipeline is to cross a lengthy bridge that has been constructed in sections such that the roadbed has expansion joints between sections. Provided the individual pipe on each section are given adequate vertical and lateral support, it may be desirable to add a TR FLEX Telescoping Sleeve at each bridge expansion joint so that the pipeline can accommodate significant movement fo the roadbed.

Yes, it is possible, but it must be done very carefully.

In a standard TR FLEX joint, the locking segment cavity and gasket seat are adjacent to each other. The joint should be retracted to engage the locking segments, a distance that will vary by size but averages less than 3/4'.

In a TR FLEX Telescoping Sleeve, the locking segments cavity and the gasket seat are separated by an appreciable distance (depending on size, this can be up to approximately one foot.) Similarly, the location of the weld bead on a plain end for Telescoping Sleeve is considerably further back from the face of the plain end than on a standard TR FLEX plain end. It is these design features working together that allow the collapse and expansion of the Telescoping Sleeve while maintaining a reliable seal throughout the range of longitudinal movement.

The TR FLEX GRIPPER® is used to accommodate field cuts of TR FLEX® Pipe. The Gripper Ring takes the place of both the locking segments and the factory applied weld bead, which would be cut off on a field cut pipe.

If it should be deemed necessary to install a Telescoping Sleeve with a Gripper Ring, it is important to consider two things:

1.  Once the Gripper Ring is tightened around the pipe installed in a Telescoping Sleeve, the ability for significant longitudinal movement is eliminated.

2.  Prior to tightening the Gripper Ring, it must be determined that the pipe has not been pulled out past the gasket, which would prevent achieving a seal.

One way to do this is to measure from the face of the Telescoping Sleeve to a point approximately one inch past the back of the gasket seat. Apply a band of duct tape around the circumference of the field cut pipe with the edge of the tape closest to the face of the plain end located at the distance measured. Insert the gasket and the Gripper Ring, lubricate the gasket and plain end of the pipe and insert the plain end until the edge of the duct tape is flush with the face of the bell. After ensuring the Gripper Ring is square on the pipe, tighten the torque-limiting bolts of the Gripper Ring until the heads snap off.

If at all possible, check to be sure that the gasket is in place and fully compressed between the inside of the Telescoping Sleeve and the outside of the plain end of pipe.

If you want to learn more, please visit our website Pipe Cap Supplier.

Cast iron is a generic name for any high carbon molten iron poured as a casting. When used to refer to pipe, cast iron (sometimes called gray iron) is a specific type in which the free graphite (Carbon) is in the shape of flakes. Cast Iron pipe were introduced into the United States in . 
 

Ductile Iron is a specific type of cast iron in which the free graphite is in the shape of nodules or spheroids. (Other names for ductile iron are nodular iron or spheroidal graphite iron.) Ductile Iron Pipe were introduced to the market in . 

Although nearly identical chemically, the two irons are quite different metallurgically. The now obsolete standard for Cast Iron Pipe (ANSI/AWWA A21.6/C106) required an iron strength of 18/40 (18,000 psi Bursting Tensile Resistance and 40,000 psi Ring Modulus of Rupture.) Although tensile testing was not a requirement of this standard, a tensile test of gray cast iron pipe would give a test result of approximately 20,000 psi Ultimate Tensile Strength, with no measurable Yield Strength or Elongation. 

The current standard for Ductile Iron Pipe (ANSI/AWWA A21.51/C151) requires a minimum grade of 60-42-10 (60,000 psi Ultimate Tensile Strength, 42,000 psi Yield Strength, and 10% Elongation.) In addition, Ductile Iron Pipe manufactured under this standard are required to meet a minimum of 7 ft lbs impact resistance by the Charpy test. (Compare Gray Iron Pipe with an impact resistance of approximately 2 ft lbs or less.) 

The difference in the physical properties of these two materials is attributable almost entirely to the difference in the shape of the free graphite. The shape of the graphite is determined at the instant of solidification and is made nodular by the addition of magnesium to the molten iron bath. Although Cast Iron was the best engineering material available for pipe production for nearly five hundred years, the development of Ductile Iron Pipe provides a far superior product.

U.S. Pipe's primary method of thrust restraint are restrained joints.

A column of liquid moving through a pipeline has momentum or force that tends to separate the joints at changes in direction (bends and tees), stops (plugs, caps, or closed valves), and changes in size (reducers). Some means must be used to prevent joint separation to maintain the integrity of the pipeline. Three such means are thrust blocks, tie rods, and restrained joints.

Thrust blocks are usually poured-in-place concrete.  They must be engineered with full knowledge of the pipeline operating characteristics and of soil type and bearing strength. They must bear against virgin soil, because thrust forces in the pipeline are transmitted through the thrust block to the soil.  Depending on these conditions, thrust blocks can be quite massive. The use of thrust blocks can delay completion of the project to allow the concrete to cure adequately before applying test pressure to the pipeline. If future construction disturbs the thrust block or the surrounding soil, joint restraint and the integrity of the pipeline can be jeopardized.

Tie rods usually involve some sort of fabricated steel harness on either side of the joint held together by tie-rods. This type of joint restraint is generally labor intensive. A tie-rod type of joint restraint must be adequately protected against weakening by corrosion, or else the joint restraint and integrity of the pipeline can be jeopardized.

Restrained joints are designed to hold the joint together against a rated pressure while the pipeline transfers the thrust force to the surrounding soil envelope. In order to calculate the footage of restrained pipeline necessary for the thrust force to be fully dissipated to the soil, it is necessary to know pipe diameter, maximum anticipated internal pressure, depth of cover, soil type, and trench construction type, as well as the configuration (e.g., bend angle) requiring restraint. The calculated restrained footage must be installed on each side of the fitting. Since polyethylene encasement for external corrosion protection reduces the friction between the pipeline and the surrounding soil, the calculated restrained footage is usually multiplied by a factor of 1.5 for pipelines where polyethylene encasement is to be installed.

Mechanical joint retainer glands, both common and proprietary design, are available for use where such devices must be used (e.g., a special valve or meter). However, U.S. Pipe does not recommend their use. Restrained push-on joints manufactured by U.S. Pipe are less susceptible to external corrosion, offer appreciably more deflection, and are much less labor-intensive to install.

Because buried Ductile Iron pipelines are electrically discontinuous and are essentially grounded for their entire length, overhead AC power lines normally don't impose corrosion or safety concerns.

A consequence of AC power lines and buried pipelines sharing rights-of-way is that AC voltages and currents can be induced by magnetic induction on the pipelines. The magnitude of the induced voltage and current on the pipeline is a function of a number of variables, including the length of pipeline paralleling the AC power line, the longitudinal resistance of the pipeline, and the resistance of the pipeline coating.

Ductile Iron pipe is manufactured in nominal 18- and 20-foot lengths and employs a rubber-gasketed jointing system. These rubber-gasketed joints offer electrical resistance that can vary from a fraction of an ohm to several ohms but nevertheless is sufficient for Ductile Iron pipelines to be considered electrically discontinuous. In effect, the rubber-gasketed joints normally segment the pipe, restricting its electrically continuous length, and prevent magnetic induction from being a problem. Also, in most cases, Ductile Iron pipelines are installed bare with only a standard 1-mil asphaltic coating and therefore are effectively grounded for their entire length, which further prevents magnetic induction on the pipeline.

During construction of Ductile Iron pipelines in the vicinity of overhead AC power lines, certain safety precautions should be followed, e.g., 'limit of approach' regulations governing construction equipment, grounding straps, chains attached to rubber-tired vehicles to provide a ground, grounding mats, etc., especially if safety concerns are heightened due to the use of joint bonding and dielectric coatings.

To install the gasket correctly in the groove in the bell, it must be uniformly distributed around the interior of the bell circumference. To do this, the gasket must be looped as it is initially placed in the bell. As a general rule:

4' through 12' gaskets generally require one loop. In cooler weather it may be easier to install the 10' and 12' gaskets using two loops placed at the twelve and six o'clock positions.

14' through 20' gaskets generally require two loops but three may be necessary, placed at the twelve and six o'clock positions.

24' through 36' gaskets generally require four loops, spaced approximately 90° apart. Put the bottom loop in first to prevent debris from being introduced into the joint.

42' and 48' gaskets generally require six loops, spaced equally around the circumference of the bell. Put the bottom loop in first to prevent debris from being introduced into the joint.

54' through 64' gaskets generally require eight loops, spaced equally around the circumference of the bell. Put the bottom loop in first to prevent debris from being introduced into the joint.

In cooler weather, it is usually a good idea to warm the gaskets before trying to install them or store them in a warm environment.

Never lubricate the gasket or gasket groove prior to installation of gasket into the bell.

Potable Water
This is by far the most common application for Ductile Iron Pipe. Because of its reliability and durability, it is the ideal choice for the transmission and distribution of potable water. The value of potable water is rapidly increasing. Water lost between the treatment plant and the customer's meter is revenue lost. From the aspect of protecting the public health, it is vitally important to protect water quality from treatment to point of use. With the exception of some special linings for sewer service, virtually all of the products marketed by U.S. Pipe & Foundry are approved by the National Sanitation Foundation (NSF) for the conveyance of potable water.

Fire Protection
Historically, the primary purpose for developing a system to distribute water was for fighting fire. The concern for the protection of lives and property was paramount, even above that of providing water for drinking and sanitation. A fire protection system must be absolutely reliable and fully functional at all times. Factory Mutual is an insurance organization with a focus on risk management and the prevention of property loss. In that role, they are particularly interested in fire protection systems, most of which are 12' and smaller. Most of the products 12' and smaller marketed by U.S. Pipe and Foundry are approved by Factory Mutual for use in fire protection systems.

The National Fire Protection Association is a national organization that promulgates codes and standards dedicated to fire safety and prevention. It is common for one such body to recognize and accept standards written by another organization, and to incorporate them into their own. Many of the NFPA Standards for fire protection systems incorporate the same American Water Works Association Standards to which U.S. Pipe and Foundry manufactures its products.

Wastewater
Ductile Iron pipe and fittings are ideally suited for wastewater systems. Wastewater pipelines fall into two categories: gravity sewers and force mains. A leaking sewer line can spread contaminated wastewater to the groundwater system. Infiltration and inflow (I&I) can overburden the wastewater treatment plant, since every gallon flowing to the plant must be treated. Severe I&I also leads to extremely excessive treatment costs. It is important to specify and install a durable piping material with reliable joints. U.S. Pipe's TYTON JOINT® and TR FLEX® Pipe joints are bottle-tight, preventing both I&I and exfiltration.

In a gravity sewer system, wastewater flows downhill through the force of gravity. Gravity systems generally do not flow full, which can lead to septic sewage transformations that can lead to hydrogen sulfide gas being converted to concentrated sulfuric acid, which is very aggressive toward cement mortar linings and Ductile Iron. In a properly designed and constructed gravity sewer system, there will be adequate slope to provide a self-cleaning velocity (generally accepted as 2 ft/sec.). Under these conditions, a standard cement mortar lining will provide adequate corrosion protection for the pipeline. For less than optimum conditions, PROTECTO 401', a ceramic epoxy lining, is recommended.

Gravity sewers must often be installed at great depths in order to achieve adequate slope. The inherent strength of Ductile Iron enables it to withstand the external loads imposed by the earth at greater depths. As the gravity sewer increases in depth, it will reach a practical limit. At this point in the project, wastewater is collected at a pumping station. The discharge line from the pump station is then a force main, since the wastewater is pumped under pressure.

A sewer force main operates as a pressure line. It does not have to be installed to a precise grade. For maximum hydraulic efficiency it should flow full at all times. This generally requires air relief valves at all high spots in the pipeline. When the pipe is kept full, there is no opportunity for hydrogen sulfide gas to collect, which virtually eliminates the possibility of septic sewage transformations. A standard cement mortar lining is usually adequate to protect the pipeline. Other linings, such as PROTECTO 401', are available if the designer so specifies.

Reclaimed Water
A reclaimed water pipeline conveys treated wastewater for beneficial re-use. Only products meeting the requirements for potable water should be specified for reclaimed water, since, ultimately, reclaimed water usually ends up in the potable water supply system.

Digester Gas ' Not!
Ductile Iron pipe and fittings are not suitable for digester gas service; thus, U.S. Pipe will not knowingly supply products for such a project. At one time, the ANSI A21.52 and A21.14 standards governed the manufacture of Ductile Iron pipe and fittings (respectively) for gas service. These standards were withdrawn a number of years ago. Ductile Iron pipe for gas service was required to undergo special processing and testing. The equipment needed is no longer available at any U.S. Pipe facilities.

Appendix A of ANSI/AWWA C151/A21.51, Ductile Iron Pipe, Centrifugally Cast, for Water, contains the minimum metal wall thickness required for 2, 3, and 4 threads for different diameter threaded outlets and different diameter pipe. Information is given for both threads conforming to Standard ANSI/ASME B1.20.1 (a.k.a. National Pipe Thread (NPT), Iron Pipe Thread (IP), or Standard Taper Pipe Thread) and AWWA C800 (a.k.a. Mueller Thread, cc thread, Corp Stop Thread). To assure adequate metal thickness for a particular pipe diameter and Pressure or Thickness Class, it is necessary to subtract the casting tolerance found in the Table in Section 4.4.2 from the Nominal Metal Wall thickness found in Table 1 of ANSI/AWWA C151/A21.51.

Concerning the security of a two engaged threads engagement, the Ductile Iron Pipe Research Association (DIPRA) conducted a study of ¾-inch and 1-inch corporation stops direct tapped into 6' Pressure Class 350 pipe. The tests were conducted on pipe sections with less than nominal metal wall thickness. After multiple corporation stops were installed in each piece of pipe under city line pressure, the installations were observed for leakage through the threads.  The water pressure was then raised to 1,000 psi in an effort to fail the 6' pipe and threaded connection. Leakage was not observed at the threaded connection. These tests were conducted with and without 3-mil thread sealing tape applied to the threads of the corporation stop. The installed corporation stops were then subjected to pull-out and cantilever load tests.  In the pull-out tests, the corporation stop failed at loads in excess of 6,500 pounds of force. The pipe threads were undamaged in each of the three tests. In the cantilever load tests, the corporation stops failed at bending moments in excess of 385 foot-pounds of force. Again the threads in the ductile iron pipe wall were undamaged. 

It can be clearly seen that work crews can direct tap service connections into Pressure Class Ductile Iron pipe under pressure, effecting structurally secure, watertight seals. It is recommended that two layers of 3-mil thread sealant tape be applied to the corporation stop threads to achieve a watertight service connection using a minimal tightening torque.

The results of this study have been published by the Ductile Iron Pipe Research Association under the title Direct Tapping of 6-inch Pressure Class 350 Ductile Iron Pipe and is available through the Web Site http://www.dipra.org.

For more Seamless Steel Pipe Supplierinformation, please contact us. We will provide professional answers.