Sign in
Explore Guest Blogging Opportunities at Voude Blog: Your Online Diary Platform
Explore Guest Blogging Opportunities at Voude Blog: Your Online Diary Platform
Your Position: Home - Physical Therapy Equipments - A novel integrated angioscope-laser system for ...
Guest Posts

A novel integrated angioscope-laser system for ...

Jul. 15, 2024

A novel integrated angioscope-laser system for ...

Conclusion: According to our knowledge, this is the first attempt to ablate carotid atherosclerotic plaques assisted by the ZebraScope' in vitro . The protective and dissecting device on the tip of the angioscope makes it safe and visible when the ablation is performed to carotid atherosclerotic plaques. The Ho:YAG laser and TFL are effective and safe for ablating the plaque in vitro .

View Details

Results: All the carotid atherosclerotic plaques were completely ablated by Ho:YAG laser and/or TFL. The Ho:YAG laser was more effective for the atherosclerotic plaques with severe calcification, while the TFL was more suitable for those with moderate calcification. There were still some thermal injury spots on the inner wall of the parent carotid artery caused by the laser in the non-protected group B. In the protected group A, on the contrary, there was no even a thermal injury spot was found on the relevant location except for one sample. The difference of ablating duration was statistically significant between group A (36.5 ± 4.79 min) and group B (63.4 ± 6.55 min) ( P < 0.01).

Methods: In this study we established a novel interventional system in vitro to take advantage of both CEA and CAS. Twenty consecutive carotid atherosclerotic plaques were harvested from the patients who underwent CEA. The plaques were randomized into two groups and inserted into the pruned and sutured descending aortas of the swine in vitro . The ZebraScope' was modified with a protective device on its flexible tip, so that the plaque could be dissected from the wall of parent carotid artery and ablated completely without damage to the carotid artery. The holmium:YAG (Ho:YAG) and thulium fiber laser (TFL) generators were alternately used when needed.

Introduction: Atherosclerotic extracranial carotid artery stenosis accounts for about 20%'30% of all strokes, which is one of the leading causes of adult morbidity and mortality. Although carotid endarterectomy (CEA) is still the mainly operational manner for atherosclerotic carotid artery stenosis/occlusion (ACAS/ACAO), and carotid angioplasty and stenting (CAS) have been used as an alternative, both CEA and CAS have limitations of their own, such as extensive invasiveness and in-stent restenosis.

Introduction

Large vascular occlusion or stenosis, including extra and intracranial large artery, is a very common cause of ischemic stroke. It accounts for about 4%'46.6% of ischemic strokes in population-based studies from the west to the east (1'10). Extracranial internal carotid artery stenosis, especially the ACAS/ACAO, is the most leading cause of large artery stroke accounting for about 20%'30% of all ischemic strokes (11'13). CEA, as the golden standard treatment for carotid stenosis, distinctly reduces the risk of recurrent stroke of patients with symptoms such as stroke or transient ischemic attack (14). CAS has been developed as an alternative to CEA for treating carotid stenosis without necessitating surgery. Both CEA and CAS are equally effective in preventing recurrent stroke in the first 4-year following procedures (15), but recurrent stenosis, compared with CEA, is found to be more common after CAS. On the other hand the risks of peri-procedural myocardial infarction, cranial nerve palsy and access site hematoma caused by CEA should not be neglected (16). The best treatment approach for patients with symptomatic carotid stenosis (occlusion) remains to be determined in the long term. To grope for a new approach for ACAS/ACAO is what we concern about. In this study in vitro, we established a model to simulate the conditions of ACAO and verified the efficacy and safety of the novel integrated angioscope-laser system.

Materials and methods

The modified ZebraScope'

ZebraScope' (Anhui Happiness Workshop Medical Equipment Co.; Ltd, China) was a single-use flexible ureteroscope which was initially used for the examination or treatment of calculuses in the ureter and renal pelvis (Figure 1). In this study we used it as an angioscope. The ZebraScope' was composed mainly of angioscope body and imaging host (Version: XFGC-UZ-A). The angioscope had a flexible distal segment with the length of 5'cm, which could be curved up or down even to 275° with a smallest radius of 8'mm in the same plane by the controller on the handle. The coaxial design for the canals of imaging data wire and fiber (shared with the irrigation canal) made the whole body of the scope to twist with a 1':'1 torque. The Complementary Metal Oxide Semiconductor (CMOS) on the tip of the scope with a diameter of 7.4'F and a high definition of 160,000'pixels, assisted with a sustainable normal saline irrigation at a flow of 50'ml/min, made it easy to operate in the carotid artery and gave us a clear field of view. To prevent the media of the carotid artery from being damaged by the laser, we designed an arc-shaped spade made by stainless steel with a radius angle of 180'220° (0.1'mm thickness) and fixed it on the tip of the angioscope (Figure 2). The fiber tip should be kept about 0.5'mm proximally to the anterior edge of the spade, so that the plaque could be dissected step by step from the wall of carotid artery by the spade and ablated by laser from the fiber (Figure 3).

FIGURE 1

Figure 1. Zebrascope was composed by scope handle, scope body and data wire. There was an entrance on the handle through which the laser fiber was introduced into the scope body. During the procedure, the surgeon could rotate the handle and curve the flexible tip of the scope body up and down through the controller on the handle.

FIGURE 2

Figure 2. Arc-shaped spade was fixed on the tip of the angioscope. The spade was made by stainless steel with a radius angle of 180'220° (0.1'mm thickness). The arc-shaped spade had two kinds of functions, one was for dissecting the plaque from the wall of internal carotid artery by rotating and pushing the scope handle, the other was to be used as a physical barrier to protect the artery wall from being injured by the lasers.

FIGURE 3

Figure 3. (A) Ablating without protective device. Procedure under this condition usually caused injury to the wall as many thermal injury spots were seen with naked eyes. (B) Ablating under the protection of a spade with a radius angle of 180°. To get a good protection to the artery wall, the spade with a radius angle of 180° was firstly used with the optical fiber in a diameter of 200'μm. (C) Ablating under the protection of a spade with a radius angle of 220°. To get a good protection to the artery wall, the spade with a radius angle of 220° was firstly used with the optical fiber in a diameter of 165'μm.

The Laser systems and fibers

The Ho:YAG laser generator (Version: SRM-H1B) with a wavelength of 'nm and the super pulsed TFL generator (Version: SRM-T1F) with a wavelength of 'nm were provided by Raykeen Laser Technique Co, Ltd, Shanghai, China (Figure 4). Single-use laser fibers with core diameters of 165'µm and 200'µm were used for TFL and Ho:YAG laser respectively.

FIGURE 4

Figure 4. Laser generator of holmium:YAG and thulium. Usually, the body of laser generator of Holmium:YAG was larger than that of Thulium. And the latter seemed more effective in the plaques without severe calcification.

Artificial atherosclerotic carotid artery occlusion

Twenty consecutive carotid atherosclerotic plaques were harvested from the patients who underwent CEA. Ultrasound and computed tomography angiography (CTA) were used to evaluate the characters and calcification degree of the plaques before CEA, The plaques' characters were confirmed by ultrasound (stable vs. vulnerable'='8:12); Ultrasonographic criteria of stable plaque was defined as that with thicker and holonomic fiber cap, little lipid core, while the plaque with thinner or incomplete fiber cap, large lipid core, ulceration, vasa vasorum intraplaque confirmed by contrast-enhanced ultrasound was classified as the vulnerable. CTA not only showed the stenosis but also the calcification degree, the length of calcification <1/4 perimeter of internal carotid artery was recorded as '+', that between 1/4 and 1/2 perimeter was recorded as '++', and that >1/2 perimeter was recorded as '+++'. Having been soaked in the formalin for at least one week and recorded with their volume measured by drainage method, the plaques were randomized into two groups (A/B, with/without protective device on the tip of the angioscope) and inserted into the pruned and sutured descending aortas of the swine in vitro (Figure 5). These artificial carotid arteries carrying atherosclerotic plaques were used to simulate the conditions of atherosclerotic carotid artery occlusion or severe stenosis of the patients.

FIGURE 5

Figure 5. (A) Carotid artery made with a pruned and sutured descending aorta. (B) Atherosclerotic carotid artery plaque from the patient. It was confirmed as a stable plaque by ultrasonography. (C) We inserted the plaque into the 'carotid artery' to make an atherosclerotic carotid artery occlusion state.

Experimental procedure

The descending aortas of the swine in the '80°C refrigerator were taken out and put into the cold water for a 5-minute thawing. After being thawed, they were pruned and sutured into the carotid arteries with an inner diameter of 5'mm and a length of 15'cm. The volume of each plaque measured by drainage method was recorded, and then the plaque was inserted into the artificial carotid artery. In this way the artificial carotid arteries carrying atherosclerotic plaques were made and put into the test cubes in the ice-cold normal sodium for laser ablating. When the operation started, the irrigational flow was controlled as 50'ml/min by the peristaltic pump. The irrigational saline from the 3-litre-bag was kept at an ordinary temperature. All the plaques were ablated completely. The volume of ablated plaque tissue in each sample ranged from 0.38 to 0.58'ml, which was list on Table 1. The size of the debris was 50'100'µm. All the debris could be rinsed out by the irrigating saline in this study in vitro. When we apply this system to the patient in the real world, a balloon catheter system was used (12'14'F balloon guiding catheter (BGC), as the first one, was used for delivering the integrated angioscope-laser system and occluding the proximal CCA; the second (4'F) and the third (2'F) ones were used to occlude the ICA distal to the plaque and the origin of ECA respectively). With the inflating of balloon catheter system, the plaque would be immerged in the normal saline with ordinary temperature without any blood. The saline would not be irrigated into the brain, it would be drained through the gap between the first balloon catheter and the integrated angioscope-laser system. To avoid the ipsilateral ischemia, the second balloon catheter was designed with two cavities, one was for inflating the balloon, and the other was for the delivering of blood from the patient's femoral artery into the ipsilateral hemisphere. The volume of each plaque, duration of ablation for each plaque, thermal injury spots on the inner wall of the carotid artery, calcification degree, and characters of plaques (vulnerable/stable) were recorded down and listed on Table 1.

TABLE 1

Table 1. Volume of plaques, duration of ablation, thermal injury spots, calcification degree, and characters of plaques in Group A and B.

Statistical analyses

Data were analyzed by using post-hoc test of variance (ANOVA) by the IBM SPSS Software (version 26.0). Data results were showed as Mean'±'SD. A p-value of 0.05 or less was considered significant.

Results

The difference of the volume (group A, 0.46'±'0.07'ml; group B, 0.46'±'0.06'ml) and calcification degree of the plaques between group A and B was not statistically significant (P'>'0.05). The difference of ablating duration was statistically significant between group A (36.5'±'4.79'min) and group B (63.4'±'6.55'min) (P'<'0.01). The difference of number of thermal injury spots was statistically significant between the two groups (P'<'0.01) (Figure 6).

FIGURE 6

Figure 6. (A) Many thermal injury spots were found in the inner wall of the 'carotid artery' after the ablating of the plaque without protection. (B) No thermal injury spots were found in the inner wall of the 'carotid artery' after the ablating of the plaque with spade-protection.

Discussion

CEA and CAS have emerged in succession as the effective measures for the prevention of stroke in patients with symptomatic and asymptomatic severe carotid artery stenosis (15, 17, 18). To minimize the damage to the intima or media is the soul of CEA. Any other operation modality, as a non-inferior or superior alternative to CEA or CAS, must have this characteristic first. The second characteristic of an ideal operation modality for ACAO/ACAS must be minimal invasive to the patients. The third must be less of durations and convenient for popularizing. The forth must keep a normal perfusion to the brain during the procedures and the fifth must have lower rate of embolic and restenosis. As a matter of fact, both CEA and CAS still have the limitations of their own, such as extensive invasiveness and in-stent restenosis.

Laser angioplasty, accompanied by enthusiastic expectations, emerged as an endovascular technique for peripheral arterial revascularization at the end of s. It was very appealing that laser had the potential to ablate atherosclerotic plaque and restore the normal anatomy through minimal invasive approach. From the end of s to s, there were a lot of researches about the safety and feasibility of using laser for ablating atherosclerotic plaque, as well as the unique feature of different kind of laser (19,20). However, the enthusiasm declined as the fact of lower long-term patency rates after initial procedures (21). As a true step forward in the endovascular treatment of occlusive disease (22), excimer laser angioplasty nowadays is commonly used in the field of peripheral artery disease (atherosclerotic plaques) and has shown a satisfied outcome with a mean follow-up of 15'±'7 months. The primary patency was 65%'±'20% and the mean distal embolism rate during the procedure was 5% (23). But excimer laser alone couldn't finish the angioplasty without balloons, and for a chronic white fibrous thrombus the excimer laser was not effective. With the problem of embolic and punctured injury, utility of laser in coronary artery occlusion was also limited. We thought that these unsatisfied results were caused by inappropriate kinds of lasers and incomplete ablating. The laser could only remove partially or totally the plaque itself, but with the thickened intima left on the media. Laser alone could not get the same results at an anatomical level as that of CEA. So we can't use this modality for ACAO or ACAS directly.

Ho:YAG laser, as the first candidate for lithotripsy because of its property to fragment all stone compositions, efficiencies and safety profiles, has been used for three decades (24,25). It operates at 2,120'nm in pulsed mode and is highly absorbed in liquid water. In pulsed mode, the sudden formation of a vapor bubble after emission could make calculus and hard tissue broken into pieces. This interaction with water also makes it safe with an optical penetration depth limited to 400'μm. As the latter, the Super Pulsed TFL comes with potential advantages over Ho:YAG laser such as higher ablation volumes during lithotripsy and production of thinner particles (26'30). For TFL, it has been optimized to emit at a wavelength of 1,940'nm, which is closely matching the near-infrared absorption peak of liquid water at 22°C (31). Because the absorption coefficient of the TFL is more than four-fold higher than Ho:YAG, a lower threshold and higher ablation efficiency can be expected in favor of the TFL at equivalent pulse energies.

To confirm the safety and efficacy of laser for ablating carotid atherosclerotic plaque is what we concern most. Even to this day there are still some primary problems which limit the utility of laser in ACAO or ACAS. As we know this kind of procedures are performed under digital subtraction angiography (DSA) and without distal protection. It is an unvisualyzed operation which doesn't provide a clear field for dissecting atherosclerotic plaque from the media like that of CEA. With the five characteristics mentioned above in our minds we took the first step with the novel integrated angioscope-laser system for ACAO. This system had an integrated feature of minimal invasiveness, visualization and anatomical dissection plus laser ablation.

In this study, for different type of plaque, there were some different effects between these two kinds of lasers. we used Ho:YAG laser for those atherosclerotic plaques with severe calcification. It seemed that the TFL was more efficient for those with moderate calcification, especially for the thickened intima. This different performance to calcification might be caused by the limitation of lower power with 8'12'W. The high performance of TFL might not be shown here. With the elevating of power and frequency more and more bubbles emerged in the operation field suggesting a great jump of temperature. The irrigating flow had to be increased to get an optimal cooling environment.

Both the 180° and 220°-arc-shaped spade were effective when used with the fibers with a diameter of 200'µm and 165'µm respectively. As the limitation of the Ho:YAG laser itself, optical fibers with a core diameter of 200'μm or larger was needed (32).

Although the fiber with a smaller diameter, usually used with TFL, brought an enough irrigating flow for cooling and washing, it caused a comparative large gap in the canal of the angioscope. Because of the larger gap, an arc-shaped spade in a larger radius angle was needed in case of injury to the carotid artery. With the help of the arc-shaped spade, the atherosclerotic plaques could be dissected from the wall of parent carotid artery without any thermal injuries caused by the laser except for one plaque with severe calcification in the protected group. The only thermal injury spot was probably caused by mistake of the operator as longer procedure duration. The durations of protected group were significantly shortened compared with those in non-protected group. We attributed the difference to that the operator could precede more confidently and fast with the help of the arc-shaped spade on the tip of the angioscope.

Limitations

Some limitations to this study should be noticed. First, the two kinds of lasers were used for the preselected cases by virtue of the degree of calcification of the plaque, it was not used randomly. the second, the model of ACAO was not completely in accord with the actual. For the in situ atherosclerotic plaque, the contents of lipid core and calcified tissues usually located within the thickened intima and covered by complete or incomplete fiber cap. To separate the plaque from the media of carotid artery we should start from an incision of the intima. This was the difference between our model and the plaque in situ. Another limitation was that the ablation was not carried out in an ongoing closed circulation environment. We couldn't verify the embolic incidence as in the closed. The last, the carotid arteries were not for light microscopy because of intact of carotid artery in the protected group. Further study should be founded in a closed unidirectional circulation canal with our ACAO or ACAS model inserted. At the same time, a temporary balloon occlusion with artery-catheter-artery-bypass should be established when this utility is going to be verified in the corpses. Both angioscopy and laser atherectomy are well established techniques, although the minimal invasive and real time operation under the integrated angioscope-laser system without occluding the blood flow to brain is amazing, there is still a long way to go for the utility of this integrated angioscope-laser system to the patients in the real world. we must establish a balloon catheter system, as illustrated in the part of 'Experimental Procedure'. What's more, a more effective and safe operative related accessories should be innovated as a supplement. Such as a double cavity balloon catheter with more flexible part in the distal and more supportable part in the proximal, an angioscope with high definition of 4'K ('×'2,160'pixels) will give us more details and make the operation more precise and safer. With all the verifications above and devices innovated, our novel integrated angioscope-laser system might be an alternative for ACAO or ACAS.

Conclusion

We have designed a novel integrated angioscope-laser system for ACAO or ACAS and verified the efficacy and safety of arc-shaped spade, Ho:YAG laser and TFL. According to our knowledge, this is the first attempt to ablate carotid atherosclerotic plaques assisted by the ZebraScope' in vitro. The protective and dissecting device (arc-shaped spade) on the tip of the angioscope, designed by the author, makes it safe and visible when the ablation is performed to the carotid atherosclerotic plaques. The Ho:YAG laser and TFL, used alternately, are effective and enough for the carotid atherosclerotic plaques in vitro.

Data availability statement

The original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author/s.

Ethics statement

The studies involving human participants were reviewed and approved by Shanghai General Hospital affiliated to Shanghai Jiaotong University. The patients/participants provided their written informed consent to participate in this study. The animal study was reviewed and approved by Shanghai General Hospital affiliated to Shanghai Jiaotong University.

Author contributions

BZ wrote the manuscript and analyzed the data for the work, GZ conceived and devised the study. All authors reviewed the manuscript.

Acknowledgments

We thank Jingshen Zhang, Zhiying Luo, Jian Yu and Wang Lv for technical assistance.

Conflict of interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Publisher's note

All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.

References

1. Mettananda KCD, Eshani MDP, Wettasinghe LM, Somaratne S, Nanayakkkara YP, Sathkorala W, et al. Prevalence and correlates of carotid artery stenosis in a cohort of Sri Lankan ischaemic stroke patients. BMC Neurol. () 21:385. doi: 10./s-021--1

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Kolominsky-Rabas PL, Weber M, Gefeller O, Neundoerfer B, Heuschmann PU. Epidemiology of ischemic stroke subtypes according to TOAST criteria: incidence, recurrence, and long-term survival in ischemic stroke subtypes: a population-based study. Stroke. () 32:'40. doi: 10./hs.

PubMed Abstract | CrossRef Full Text | Google Scholar

3. Wolma J, Nederkoorn PJ, Goossens A, Vergouwen MD, van Schaik IN, Vermeulen M. Ethnicity a risk factor? The relation between ethnicity and large- and small-vessel disease in white people, black people, and asians within a hospital-based population. Eur J Neurol. () 16:522'7. doi: 10./j.-...x

PubMed Abstract | CrossRef Full Text | Google Scholar

Additional reading:
How Long Can Surgical Staples Stay Safe?
4 Tips to Select the Right Disposable Trocar for Endoscopy
How to Choose the Right Disposable Trocar?
How Does the New Electric Car Charge?
What Is a Gia Bowel Stapler and Its Benefits?
How do I choose a machine vision camera?
Which Thoracoscopy Trocar offers the best value for purchase?

With competitive price and timely delivery, Easetak sincerely hope to be your supplier and partner.

5. Smith WS, Lev MH, English JD, Camargo EC, Chou M, Johnston SC, et al. Significance of large vessel intracranial occlusion causing acute ischemic stroke and TIA. Stroke. () 40:'40. doi: 10./STROKEAHA.109.

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Malhotra K, Gornbein J, Saver JL. Ischemic strokes due to large-vessel occlusions contribute disproportionately to stroke-related dependence and death: a review. Front Neurol. () 8:651. doi: 10./fneur..

PubMed Abstract | CrossRef Full Text | Google Scholar

7. Marulanda-Londoño E, Chaturvedi S. Stroke due to large vessel atherosclerosis: five new things. Neurol Clin Pract. () 6:252'8. doi: 10./CPJ.

CrossRef Full Text | Google Scholar

8. Liu L, Wang D, Wong KS, Wang Y. Stroke and stroke care in China: huge burden, significant workload, and a national priority. Stroke. () 42:'4. doi: 10./STROKEAHA.111.

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Wang Y, Zhao X, Liu L, Soo YO, Pu Y, Pan Y, et al. Prevalence and outcomes of symptomatic intracranial large artery stenoses and occlusions in China: the Chinese intracranial atherosclerosis (CICAS) study. Stroke. () 45:663'9. doi: 10./STROKEAHA.113.

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Petty GW, Brown RD Jr, Whisnant JP, Sicks JD, O'Fallon WM, Wiebers DO. Ischemic stroke subtypes: a population-based study of incidence and risk factors. Stroke. () 30:'6. doi: 10./01.str.30.12.

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Palm F, Dos Santos M, Urbanek C, Greulich M, Zimmer K, Safer A, et al. Stroke seasonality associations with subtype, etiology and laboratory results in the ludwigshafen stroke study (LuSSt). Eur J Epidemiol. () 28:373'81. doi: 10./s-013--4

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Timsit SG, Sacco RL, Mohr JP, Foulkes MA, Tatemichi TK, Wolf PA, et al. Early clinical differentiation of cerebral infarction from severe atherosclerotic stenosis and cardioembolism. Stroke. () 23:486'91. doi: 10./01.str.23.4.486

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Barnett HJ, Taylor DW, Eliasziw M, Fox AJ, Ferguson GG, Haynes RB, et al. Benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis. North American symptomatic carotid endarterectomy trial collaborators. N Engl J Med. () 339:'25. doi: 10./NEJM

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Brott TG, Hobson RW 2nd, Howard G, Roubin GS, Clark WM, Brooks W, et al. Stenting versus endarterectomy for treatment of carotid-artery stenosis. N Engl J Med. () 363:11'23. doi: 10./NEJMoa

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Mas JL, Trinquart L, Leys D, Albucher JF, Rousseau H, Viguier A, et al. Endarterectomy versus angioplasty in patients with symptomatic severe carotid stenosis (EVA-3S) trial: results up to 4 years from a randomised, multicentre trial. Lancet Neurol. () 7:885'92. doi: 10./S-(08)-9

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Brott TG, Howard G, Roubin GS, Meschia JF, Mackey A, Brooks W, et al. Long-Term results of stenting versus endarterectomy for carotid-artery stenosis. N Engl J Med. () 374:'31. doi: 10./NEJMoa

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Huppert PE, Duda SH, Seboldt H, Claussen CD. Dye laser-assisted angioplasty with multifiber catheters: short-term results in the treatment of 29 peripheral arterial occlusions. AJR Am J Roentgenol. () 157:'7. doi: 10./ajr.157.6.

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Huppert PE, Duda SH, Helber U, Karsch KR, Claussen CD. Comparison of pulsed laser-assisted angioplasty and balloon angioplasty in femoropopliteal artery occlusions. Radiology. () 184:363'7. doi: 10./radiology.184.2.

PubMed Abstract | CrossRef Full Text | Google Scholar

22. Garnic JD, Hurwitz AS. Endovascular excimer laser atherectomy techniques to treat complex peripheral vascular disease: an orderly process. Tech Vasc Interv Radiol. () 8:150'9. doi: 10./j.tvir..04.003

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Jayet J, Coscas R, Heim F, Goeau-Brissonniere O, Javerliat I, Chakfe N, et al. Laser uses in noncoronary arterial disease. Ann Vasc Surg. () 57:229'37. doi: 10./j.avsg..06.010

PubMed Abstract | CrossRef Full Text | Google Scholar

28. Keller EX, De Coninck V, Doizi S, Daudon M, Traxer O. Thulium fiber laser: ready to dust all urinary stone composition types? World J Urol. () 39:'8. doi: 10./s-020--9

PubMed Abstract | CrossRef Full Text | Google Scholar

29. Panthier F, Doizi S, Lapouge P, Chaussain C, Kogane N, Berthe L, et al. Comparison of the ablation rates, fissures and fragments produced with 150'µm and 272'µm laser fibers with superpulsed thulium fiber laser: an in vitro study. World J Urol. () 39:'91. doi: 10./s-020--z

PubMed Abstract | CrossRef Full Text | Google Scholar

30. Traxer O, Keller EX. Thulium fiber laser: the new player for kidney stone treatment? A comparison with holmium:yAG laser. World J Urol. () 38:'94. doi: 10./s-019--5

PubMed Abstract | CrossRef Full Text | Google Scholar

31. Jansen ED, van Leeuwen TG, Motamedi M, Borst C, Welch AJ. Temperature dependence of the absorption coefficient of water for midinfrared laser radiation. Lasers Surg Med. () 14:258'68. doi: 10./lsm.

PubMed Abstract | CrossRef Full Text | Google Scholar

Revolutionary Cold Laser Treatment for Carotid Blockage: Your ...

 

Easetak Product Page

Have you or a loved one been diagnosed with carotid blockage? Are you concerned about the risks and complications associated with traditional treatment options such as surgery or medication? If so, you're not alone. Many people facing carotid blockage are searching for alternative treatments that are less invasive, more effective, and have fewer side effects. That's where cold laser therapy comes in.

Cold laser therapy, also known as low-level laser therapy (LLLT), is a revolutionary new treatment that uses low-intensity laser light to stimulate healing and improve circulation in the affected area. In recent years, cold laser therapy has been gaining popularity as a safe and effective alternative treatment for a variety of conditions, including carotid blockage.

But what exactly is cold laser therapy, and how does it work to treat carotid blockage? In this blog post, we'll address some of the most common questions and concerns surrounding this innovative treatment approach.

What is cold laser therapy?

Cold laser therapy is a non-invasive treatment that uses low-intensity laser light to stimulate healing and reduce inflammation in the body. The laser light penetrates the skin and is absorbed by the cells, where it helps to stimulate the production of new healthy tissue, improve blood flow, and reduce pain and inflammation.

Unlike traditional surgical procedures, cold laser therapy does not involve any incisions or anesthesia, making it a safe and painless treatment option for many patients. In addition, cold laser therapy has been shown to have minimal side effects and can be used in conjunction with other treatments to enhance their effectiveness.

How does cold laser therapy work for carotid blockage?

When it comes to treating carotid blockage, cold laser therapy works by targeting the affected area with low-intensity laser light. The laser light helps to stimulate the production of new healthy tissue in the carotid artery, which in turn helps to improve blood flow and reduce the risk of stroke.

In addition, cold laser therapy can help to reduce inflammation in the arteries, decrease the buildup of plaque, and improve overall circulation in the affected area. This can help to prevent further blockages from forming and reduce the risk of complications associated with carotid blockage.

What are the benefits of cold laser therapy for carotid blockage?

There are many benefits to using cold laser therapy to treat carotid blockage. Some of the most significant benefits include:

- Non-invasive: Cold laser therapy does not require any incisions or anesthesia, making it a safe and painless treatment option for many patients.

- Minimal side effects: Cold laser therapy has been shown to have minimal side effects, making it a safe and effective alternative to traditional treatments such as surgery or medication.

- Improved circulation: Cold laser therapy helps to improve blood flow in the affected area, which can help to reduce the risk of stroke and other complications associated with carotid blockage.

- Reduced inflammation: Cold laser therapy can help to reduce inflammation in the arteries, which can help to decrease the buildup of plaque and improve overall circulation.

- Enhanced healing: Cold laser therapy stimulates the production of new healthy tissue in the affected area, which can help to promote healing and reduce the risk of further blockages.

Is cold laser therapy safe for treating carotid blockage?

Yes, cold laser therapy is considered to be a safe and effective treatment option for carotid blockage. The low-intensity laser light used in cold laser therapy has been shown to have minimal side effects and can be used in conjunction with other treatments to enhance their effectiveness.

However, it's important to discuss the risks and benefits of cold laser therapy with your healthcare provider before undergoing treatment. Your healthcare provider can help you determine if cold laser therapy is a suitable treatment option for your individual needs and condition.

In conclusion, cold laser therapy is a revolutionary new treatment option for carotid blockage that offers many benefits over traditional treatments. If you or a loved one is facing carotid blockage, consider exploring the potential benefits of cold laser therapy and discussing this treatment option with your healthcare provider. Cold laser therapy has the potential to improve circulation, reduce inflammation, and promote healing in the affected area, helping to reduce the risk of stroke and other complications associated with carotid blockage.

Read more

Are you interested in learning more about Cold Laser For Carotid Blockage? Contact us today to secure an expert consultation!

Additional reading:
What kind of bed do doctors recommend?
Unveiling the Truth Behind Stomach Staples Surgery
What kind of beds are used in ICU?
What are the advantages of skin staples?
Are Luxury ICU Beds Worth the Price?
Is the Skin Stapler 35w the future of wound closure technology?
Upgrade Your Hospital with Manual Beds for Sale: Affordable and Reliable Options Available

Comments

0 of 2000 characters used

All Comments (0)
Get in Touch

  |   Transportation   |   Toys & Hobbies   |   Tools   |   Timepieces, Jewelry, Eyewear   |   Textiles & Leather Products   |   Telecommunications   |   Sports & Entertainment   |   Shoes & Accessories   |   Service Equipment